Start with the question: do you need to protect only the sample, or also the operator and the room? A laminar flow clean bench and a biological safety cabinet may look similar, but they serve different purposes. Choosing a wider work area or adding a UV lamp cannot correct the wrong choice of protection.

This guide helps you prepare an equipment enquiry. The final cabinet class and type should follow the risk assessment, laboratory procedures and instructions for the specific model.

The main differences

EquipmentMain purposeWhat to consider
Laminar flow clean benchProtecting the product or sample from airborne particlesDoes not protect the operator from hazardous biological aerosols.
Class I biological safety cabinetProtecting the operator and the environmentDoes not provide the product protection offered by a Class II cabinet.
Class II biological safety cabinetProtecting the operator, product and environment when correctly installed and usedConfirm the type, exhaust arrangement and permitted applications.
Chemical fume hoodRemoving chemical contaminants within its design limitsDoes not replace a biological safety cabinet for infectious materials.

“Laminar” describes airflow, rather than the complete level of protection. A specification therefore needs the intended application, cabinet class and airflow arrangement, not just a generic equipment name.

Three questions for the initial selection

  1. What materials will be handled? Describe the materials, their hazards and any operations that can generate aerosols. Clean benches may suit non-hazardous materials requiring a clean working zone; biological hazards require a separate assessment of containment equipment.
  2. Will volatile chemicals be used? A HEPA filter captures particles; it does not by itself address gases and vapours. Share reagent composition and quantities with the biosafety officer and equipment supplier.
  3. What facilities are available? Check ventilation, electrical supply, access routes and service clearances. Air currents from doors and ventilation outlets can affect cabinet performance.

Examples from the OSELY catalogue

ModelManufacturer-confirmed distinctionConfirm before ordering
LaboGene Fortuna Clean Bench 1200Vertical laminar airflow; product protection when handling non-hazardous materials.Work area, stand, fittings and process requirements.
LaboGene Mars 1200Class II cabinet; the manufacturer describes 70% recirculation and 30% exhaust through a HEPA filter.Permitted applications and the exhaust arrangement for the room.
LaboGene Mars B2 1200Class II Type B2 cabinet with 100% exhaust and a required duct connection.Exhaust capacity and integration with the building ventilation system.

Full exhaust does not turn a B2 cabinet into a general-purpose chemical fume hood: the manufacturer specifies application limits. Select A2 or B2 to suit the process, rather than assuming a higher designation is automatically better.

What to include in the specification

  • Materials, reagents and operations, with the required type of protection.
  • Dimensions of equipment placed inside the cabinet and the required working width.
  • Installation space, delivery route, ventilation and power supply.
  • Stand, sockets, taps and additional options as separate items.
  • Model-specific instructions and documentation, checks after installation and service terms.

Include a layout of instruments inside the cabinet. Equipment may fit on the work surface while still obstructing hand movements or air intake grilles.

Frequently asked questions

Does a UV lamp turn a clean bench into a biological safety cabinet?

No. Protection depends on the design and operation of the aerosol containment system. A lamp does not change the cabinet class.

Can I select a cabinet by width and price alone?

First establish its purpose and engineering requirements. Then compare working width, ergonomics, fittings and the full cost of delivery and installation.

Does a Class II cabinet make a laboratory Biosafety Level 2?

No. Cabinet class and laboratory biosafety level are different concepts. One cabinet does not establish the readiness of the entire facility.