Differential scanning calorimeters — selection and configuration

Differential scanning calorimetry measures heat-flow differences between a sample and a reference under a controlled temperature programme. It supports investigation of melting, crystallisation, glass transitions and material reactions.

Select equipment and request a quotation

State your method, workload and required options to prepare a comparable quotation.

Instrument selection

  • Temperature range and heating/cooling rates.
  • Sensor, crucibles and measurement atmosphere.
  • Cooling system and automatic sample changer.
  • Curve evaluation and reporting software.

Selection requires the material, sample mass and method. Calibration materials, cooling accessories and software modules are defined in the agreed specification. Explore related laboratory equipment.

Three DSC calorimeters compared

ModelKey differences
NETZSCH DSC 300 Caliris ClassicDSC 300 Caliris Classic: up to 600 °C; lower limit depends on cooling; optional ASC with up to 20 positions.
Shimadzu DSC-60A PlusDSC-60A Plus: 24-sample tray, ±150 mW, RT–600 °C or −140–600 °C with the standard chamber and LN2.
TA Instruments Discovery DSC250Discovery DSC250: Fusion Cell, Tzero and MDSC; LN2P −180–550 °C, FACS RT–725 °C; optional autosampler.

Temperature limits depend on the cooling system. Compare configurations with equivalent atmospheres, pans and required analysis modes.

See the relevant product page for its price and configuration.

Manufacturer information and documents

Check the version, supply region and document revision. A series page may describe options that are not included in the specific configuration.

Configuration, pricing and procurement

For a quotation, specify the required configuration, number of instruments, installation city and services needed. Agree options, consumables, commissioning and staff familiarisation separately. Documentation, delivery times and warranty terms are specified in the quotation and contract. See the model page for its current price or quotation request option.

Questions before selection and procurement

Which models are listed?

NETZSCH DSC 300 Caliris Classic · Shimadzu DSC-60A Plus · TA Instruments Discovery DSC250.

Does every configuration need liquid nitrogen?

No. The choice depends on minimum temperature and cooling rate. Air and mechanical coolers have different limits from LN2 systems.

What should be specified in the supply package?

Cooler, autosampler, pans, gases, calibration materials, software modules, computer and training.

How can a fixed price be obtained?

Agree the exact equipment and option list, installation, training and service. A fixed price is established for a confirmed specification; each product page provides a quotation request.