Portable medical refrigerators and freezers provide active temperature control for transporting vaccines, medicines, reagents and laboratory samples when the selected conditions match the material’s protocol. This category includes Evermed PRF/EPRF compressor models and Antech CryoExpress ultra-low temperature freezers. Equipment selection, supply and service are available in Ukraine.
Choose the technology for your temperature range
Portable compressor refrigerators and freezers for active temperature control. PRF offers compact 12 and 20 L options; EPRF extends the range to 82 L.
Stirling-based portable ultra-low temperature freezers. MMF-2 provides 25 L of space; ONE is a compact 1 L model with a built-in battery.
Compare portable refrigerators and freezers
| Series or model | Usable volume | Temperature range | Power supply |
|---|---|---|---|
| Evermed PRF 12 / 20 | 12 / 20 L | −18…+10 °C | 12/24 V DC; 110–230 V AC with an integrated transformer |
| Evermed EPRF C | 22 / 32 / 56 / 82 L | −24…+10 °C | 12/24 V DC; optional 110–230 V AC adapter |
| Evermed EPRF HC | 22 / 32 / 56 / 82 L | −24…+40 °C | 12/24 V DC; optional 110–230 V AC adapter |
| Antech CryoExpress MMF-2 | 25 L | −86…+18 °C | 12–24 V DC; 100–240 V AC |
| Antech CryoExpress ONE | 1 L | −86…+8 °C | 12–30 V DC; 100–240 V AC; built-in battery |
HC is an operating-range designation: EPRF HC reaches +40 °C inside the compartment. It does not mean an ambient-temperature limit of +40 °C; EPRF is rated for +16…+38 °C ambient conditions. The CryoExpress ONE range is specified at +25 °C ambient.
Power supply and transport planning
- Evermed PRF and EPRF require continuous external power for active cooling; they have no built-in battery. Include the optional AC adapter when an EPRF will be used on mains power.
- The MMF-2 specification does not list a standard backup battery. Plan a compatible external power source for the full route.
- CryoExpress ONE has a built-in battery; actual runtime depends on the setpoint, ambient temperature, load and door opening. Confirm the required battery configuration before ordering.
- Keep ventilation openings clear, secure the equipment and confirm the required cables, adapters, packaging and temperature monitoring.
Select equipment for vaccines, medicines and samples
Start with the permitted product temperature, usable volume, packaging dimensions, route duration and available power. The equipment range alone does not establish suitability for a vaccine, medicine or sample, and does not replace the approved cold-chain procedure.
Use a temperature data logger to document the conditions required by your process. For passive transport options, see medical thermal containers and bags.
Contact OSELYA YUT with the required temperature, load, route and power supply to confirm the appropriate model and configuration.