An infusion fluid warmer controls the heating of fluid passing through compatible tubing. It complements the delivery system but does not replace the pump that sets the flow rate. The catalogue offers the compact Sino MDT SN-H10 with UPS and the H20. Compare temperature range, permitted fluids, tubing and heating-channel configuration.
How to select equipment
Identify the fluid, target temperature and operating flow, then verify the permitted combination in the device instructions. Assess tubing length and diameter, installation and backup power. A heater setpoint is not the same as fluid temperature at the patient: performance depends on flow, tubing length and operating conditions.
Models and prices compared
| Model / package | Price, UAH |
|---|---|
| Sino MDT SN-H10 fluid warmer with UPS | 25 388.51 UAH |
| Sino MDT H20 infusion fluid warmer | 69 310.64 UAH |
Specifications and configuration scope
SN-H10 is offered with a 35–42 °C range and H20 with 32–42 °C. SN-H10 includes a UPS, with its model and runtime defined in the specification. H20 has several factory versions: a series photograph with two guides does not by itself confirm supplied channel count or Wi-Fi. Record these details in the order.
Supply list and consumables
The SN-H10 supply list specifies the warmer and UPS; the photograph shows the warmer. For H20, confirm heating channels, tubing, stand and optional features separately. Verify permitted fluids and consumables against the instructions rather than the category name. Photographed accessories should not be assumed to be included.
What to check before ordering
Provide model names, quantities, required accessories and installation conditions. Record exact versions, supply scope, training, documentation and service requirements in the specification. Catalogue prices refer to the listed offer; additional accessories are agreed separately. OSELY can help match these requirements to the selected equipment.
Frequently asked questions
Does a warmer replace a pump?
No. The warmer controls heating; the delivery system or pump determines the flow.
Which temperature ranges are listed?
SN-H10: 35–42 °C; H20: 32–42 °C. Check permitted settings for each fluid in the instructions.
Is a UPS included?
Yes, in the SN-H10 with UPS offer. Specify its model and runtime in the order. No UPS is listed for H20.
Do all H20 warmers have two channels?
No. Several versions exist. Define channel count and accessories in the order specification.