OSELYA YUT LLC — medical equipment, project support and service in Ukraine

Digital radiography systems

Sort:
View:

Equipment in the catalogue

New ANGELL configurations: MTP50-B is a 50 kW floor-mounted system. Aurora MTP65-D lists 50 kW, an electrically height-adjustable table and no computer desk. DTP576 has a dynamic 43×43 cm FPD and 50 kW; MIRAX Taurus I has a dynamic FPD, 80 kW and Canon E7254FX tube. All four list 380 V.

Fixed digital radiography systems: IMAX 8000, IMAX 8200, Mindray DigiEye 350 and ANGELL DT520, DT528, DT521, DTP580B-3 and MTP50-A. The range contains U-arm and floor-mounted systems with different equipment packages.

System types and applications

A U-arm supports the tube and receptor on a shared positioning assembly. The floor-mounted MTP50-A uses a manually operated table and separate vertical bucky stand. Choose the format for the room layout and required projections.

Configuration differences

OR Technology Amadeo R-DR is available in manual and motorised versions with one or two FPDs. All four offers list 50 kW and 100 µm pixels. Motorised versions include electric table height adjustment and tube-to-detector tracking. The computer desk is excluded.

ANGELL DT520 and DT528: 50 kW, 43×43 cm FPD, Canon E7843X; DT520 excludes a table, DT528 includes a wheeled table. DT521 lists an ANGELL dynamic FPD and Siemens tube. This DTP580B-3 package lists a wireless 3072×3072 FPD. MTP50-A: 50 kW, 380 V, manual movement.

Selection criteria

Check the generator and tube, detector, positioning hardware, table load and movement, workstation, image export and PACS compatibility. Dynamic detection, fluoroscopy and image stitching must be confirmed for the exact version.

Workplace preparation

Planning covers room dimensions, stand and table positions, electrical supply, network access and operator workplace. MTP50-A lists 380 V. Room, radiation protection and installation requirements are defined in the equipment project.

Models and prices

Model and configurationPrice
IMAX 8000 digital radiography system3 130 000.00 UAH
IMAX 8200 digital radiography system3 760 000.00 UAH
Mindray DigiEye 350 digital radiography system5 088 950.00 UAH
ANGELL DT520 digital X-ray system without patient table3 192 954.59 UAH
ANGELL DT528 digital X-ray system3 294 318.34 UAH
ANGELL DT521 digital X-ray system4 460 000.00 UAH
ANGELL DTP580B-3 digital X-ray system4 764 090.83 UAH
ANGELL MTP50-A digital X-ray system3 507 181.66 UAH
ANGELL MTP50-B digital X-ray system3 953 181.66 UAH
ANGELL Aurora MTP65-D digital X-ray system5 372 272.93 UAH
ANGELL DTP576 digital X-ray system8 891 618.34 UAH
ANGELL MIRAX Taurus I digital X-ray system10 199 209.17 UAH
Digital radiography system OR Technology Amadeo R-DR, 1 FPD6 373 999.89 UAH
Digital radiography system OR Technology Amadeo R-DR, 2 FPD6 099 999.84 UAH
Digital radiography system OR Technology Amadeo R-DR motorised, 1 FPD6 799 999.83 UAH
Digital radiography system OR Technology Amadeo R-DR motorised, 2 FPD7 600 000.11 UAH

Package and related categories

The price applies to the itemised package. Not every system includes a table, computer, printer or specialised licences. DT521 and DTP580B-3 include a platform, grid and control panel; DTP580B-3 also lists a workstation desk. Installation, training and service are defined in the specification.

ANGELL · Mobile X-ray systems · Diagnostic imaging

Frequently asked questions

How do the configurations differ?

ANGELL DT520 and DT528: 50 kW, 43×43 cm FPD, Canon E7843X; DT520 excludes a table, DT528 includes a wheeled table. DT521 lists an ANGELL dynamic FPD and Siemens tube. This DTP580B-3 package lists a wireless 3072×3072 FPD. MTP50-A: 50 kW, 380 V, manual movement.

What is included in the price?

The price applies to the itemised package. Not every system includes a table, computer, printer or specialised licences. DT521 and DTP580B-3 include a platform, grid and control panel; DTP580B-3 also lists a workstation desk. Installation, training and service are defined in the specification.

What should be checked before ordering?

Check the generator and tube, detector, positioning hardware, table load and movement, workstation, image export and PACS compatibility. Dynamic detection, fluoroscopy and image stitching must be confirmed for the exact version.

How should the workplace be prepared?

Planning covers room dimensions, stand and table positions, electrical supply, network access and operator workplace. MTP50-A lists 380 V. Room, radiation protection and installation requirements are defined in the equipment project.