Quantity
|
Total
|
||
|
|
|||
|
|
|||
Equipment in the catalogue
New ANGELL configurations: MTP50-B is a 50 kW floor-mounted system. Aurora MTP65-D lists 50 kW, an electrically height-adjustable table and no computer desk. DTP576 has a dynamic 43×43 cm FPD and 50 kW; MIRAX Taurus I has a dynamic FPD, 80 kW and Canon E7254FX tube. All four list 380 V.
Fixed digital radiography systems: IMAX 8000, IMAX 8200, Mindray DigiEye 350 and ANGELL DT520, DT528, DT521, DTP580B-3 and MTP50-A. The range contains U-arm and floor-mounted systems with different equipment packages.
System types and applications
A U-arm supports the tube and receptor on a shared positioning assembly. The floor-mounted MTP50-A uses a manually operated table and separate vertical bucky stand. Choose the format for the room layout and required projections.
Configuration differences
OR Technology Amadeo R-DR is available in manual and motorised versions with one or two FPDs. All four offers list 50 kW and 100 µm pixels. Motorised versions include electric table height adjustment and tube-to-detector tracking. The computer desk is excluded.
ANGELL DT520 and DT528: 50 kW, 43×43 cm FPD, Canon E7843X; DT520 excludes a table, DT528 includes a wheeled table. DT521 lists an ANGELL dynamic FPD and Siemens tube. This DTP580B-3 package lists a wireless 3072×3072 FPD. MTP50-A: 50 kW, 380 V, manual movement.
Selection criteria
Check the generator and tube, detector, positioning hardware, table load and movement, workstation, image export and PACS compatibility. Dynamic detection, fluoroscopy and image stitching must be confirmed for the exact version.
Workplace preparation
Planning covers room dimensions, stand and table positions, electrical supply, network access and operator workplace. MTP50-A lists 380 V. Room, radiation protection and installation requirements are defined in the equipment project.
Models and prices
Package and related categories
The price applies to the itemised package. Not every system includes a table, computer, printer or specialised licences. DT521 and DTP580B-3 include a platform, grid and control panel; DTP580B-3 also lists a workstation desk. Installation, training and service are defined in the specification.
Frequently asked questions
How do the configurations differ?
ANGELL DT520 and DT528: 50 kW, 43×43 cm FPD, Canon E7843X; DT520 excludes a table, DT528 includes a wheeled table. DT521 lists an ANGELL dynamic FPD and Siemens tube. This DTP580B-3 package lists a wireless 3072×3072 FPD. MTP50-A: 50 kW, 380 V, manual movement.
What is included in the price?
The price applies to the itemised package. Not every system includes a table, computer, printer or specialised licences. DT521 and DTP580B-3 include a platform, grid and control panel; DTP580B-3 also lists a workstation desk. Installation, training and service are defined in the specification.
What should be checked before ordering?
Check the generator and tube, detector, positioning hardware, table load and movement, workstation, image export and PACS compatibility. Dynamic detection, fluoroscopy and image stitching must be confirmed for the exact version.
How should the workplace be prepared?
Planning covers room dimensions, stand and table positions, electrical supply, network access and operator workplace. MTP50-A lists 380 V. Room, radiation protection and installation requirements are defined in the equipment project.