Antech CryoEssence 47C monitored liquid nitrogen dewar — A 47 L liquid-nitrogen vessel with temperature and level monitoring, audible and visual alarms and six round canisters for up to 9,360 straws of 0.5 mL or 21,000 straws of 0.25 mL.
LN₂ VOLUME47 LModel specifications
MONITORINGTemperature + levelModel specifications
CAPACITY21,000 strawsModel specifications
Photo: manufacturer illustration of CryoEssence 175R as a series illustration. C versions with canisters and R versions with racks differ in capacity and equipment. The selected SKU is specified in the table; monitoring and other options are included only when listed in the supply specification.
Key advantages
- Temperature and level display with local audible and visual alarms.
- Six standard round canisters for straw organisation.
- Data logging with USB and RS485 connections and a remote alarm contact.
- Lockable lid; optional Wi-Fi/cloud, backup battery and roller base.
Technical specifications
| Model | CryoEssence 47C |
|---|
| Storage phase | Liquid nitrogen |
|---|
| Monitoring | Temperature and LN₂ level |
|---|
| Alarms | Audible and visual |
|---|
| Data interfaces | USB, RS485; remote alarm contact |
|---|
| Wi-Fi / cloud | Optional |
|---|
| Power supply | 100–240 V, 50/60 Hz |
|---|
| Backup battery | Optional |
|---|
| LN₂ volume | 47 L |
|---|
| Standard canisters | 6 |
|---|
| Canister dimensions | Ø97 × 276 mm |
|---|
| Straw capacity | 9,360 × 0.5 mL or 21,000 × 0.25 mL |
|---|
| Neck opening | 127 mm |
|---|
| Static evaporation | 0.36 L/day |
|---|
| Static holding time | 131 days |
|---|
| Outside diameter | 508 mm |
|---|
| Overall height | 730 mm |
|---|
| Empty / full weight | 19.2 / 57 kg |
|---|
| Lockable lid | Yes |
|---|
| Optional roller base | RB-47 |
|---|
| SKU | 2152000 |
|---|
Application and configuration
Designed for biological-sample storage in liquid nitrogen. Monitoring supports routine inspections but does not replace the laboratory’s nitrogen-level checks and operating procedures.
Static evaporation and holding-time values describe rated test conditions. Frequent access and operating conditions change the practical refill interval.
Alternative vial and blood-bag capacities require their specified optional inventory systems and compatible sample containers. Wi-Fi/cloud, backup battery and roller base are optional.
Does it refill nitrogen automatically?
CryoEssence monitors temperature and level but is filled manually. Automatic filling is not part of the standard configuration.
Is static holding time the refill interval?
No. It is a rated value under static conditions. Actual refill intervals depend on access frequency, load and operating conditions.
All models in this category
Compare another model
Official manufacturer information
The image illustrates the series with a CryoEssence 175R; refer to the table for the selected model’s specifications.