LN₂ VOLUME35 L
NECK OPENING125 mm
MONITORINGLN₂ + temperature
CAPACITYup to 21,000 straws
Antech CryoEssence 35C - a 35 L cryogenic vessel with integrated temperature and LN₂ level monitoring for storing biological samples in the liquid phase of nitrogen. The six standard round canisters accommodate up to 9,360 cryostraws of 0.5 mL or up to 21,000 cryostraws of 0.25 mL.
CAPACITY6 round canisters · up to 9,360 cryostraws of 0.5 mL or up to 21,000 cryostraws of 0.25 mLFor the standard model configuration.
Photo: manufacturer illustration of CryoEssence 175R as a series illustration. C versions with canisters and R versions with racks differ in capacity and equipment. The selected SKU is specified in the table; monitoring and other options are included only when listed in the supply specification.
CryoEssence 35C or 47C: which model should you choose?
Both models use six round canisters of the same size and offer the same straw capacity. The 35C is more compact and lighter; the 47C adds 12 L of nitrogen and increases the rated static holding time from 97 to 131 days.
CANISTERS CryoEssence 35C
LN₂ volume35 LCapacityup to 21,000 strawsCanisters6 × Ø97 × 276 mmStatic holding timeup to 97 daysEmpty weight18 kg
Current model
ALTERNATIVE CryoEssence 47C
LN₂ volume47 LCapacityup to 21,000 strawsCanisters6 × Ø97 × 276 mmStatic holding timeup to 131 daysEmpty weight19.2 kg
Key benefits
- Real-time temperature and LN₂ level monitoring with a display and audible/visual alarms.
- up to 9,360 cryostraws of 0.5 mL or up to 21,000 cryostraws of 0.25 mL in the standard storage system.
- 6 × Ø97 × 276 mm for organised sample storage.
- Up to 97 days of static holding time under rated conditions, with an evaporation rate of 0.36 L/day.
- USB, RS485 and a remote alarm contact enable data logging and monitoring integration.
- Lockable lid; Wi-Fi/cloud, a backup battery and the RB-30 roller base are available as options.
Technical specifications
| Model | CryoEssence 35C |
| Equipment type | cryogenic vessel with monitoring and canisters |
| Storage phase | liquid phase LN₂ |
| Monitoring | real-time temperature and LN₂ level |
| Alarms | audible and visual |
| Data interfaces | USB, RS485 |
| Remote alarm | remote alarm contact |
| Wi-Fi / cloud | optional |
| Power supply | 100-240 V, 50/60 Hz |
| Backup battery | optional |
| Liquid nitrogen volume | 35 L |
| Straw sizes | 0.5 mL / 0.25 mL |
| Straw capacity | up to 9,360 cryostraws of 0.5 mL or up to 21,000 cryostraws of 0.25 mL |
| Standard canisters | 6 pcs |
| Canister size | Ø97 × 276 mm |
| Neck diameter | 125 mm |
| Static evaporation rate | 0.36 L/day |
| Static holding time | up to 97 days |
| External diameter | 451 mm |
| Overall height | 805 mm |
| Empty / filled weight | 18 / 46 kg |
| Lockable lid | yes |
| Roller base | RB-30, optional |
| Manufacturer / series | Antech / CryoEssence |
| Article number | 2151000 |
Applications and limitations
CryoEssence 35C is designed for monitored storage of biological samples in cryostraws in the liquid phase of nitrogen. Monitoring reduces the risk of an unnoticed deviation but does not replace routine LN₂ level checks or the laboratory’s standard operating procedures.
The actual refill interval depends on operating conditions, opening frequency and loading. The standard configuration is designed for 0.5 and 0.25 mL straws; other sample carriers require a separate compatible storage system. Wi-Fi/cloud, the backup battery and the roller base are not included in the standard configuration.
Work with liquid nitrogen in a ventilated area using cryogenic protective equipment. View protective equipment →
Does it refill nitrogen automatically?
CryoEssence monitors temperature and level but is filled manually. Automatic filling is not part of the standard configuration.
Is static holding time the refill interval?
No. It is a rated value under static conditions. Actual refill intervals depend on access frequency, load and operating conditions.
All models in this category
Antech manufacturer catalogue
The image illustrates the series with a CryoEssence 175R; refer to the table for the selected model’s specifications.