For storage of medicines and other pharmaceutical products at +2 to +10 °C. Gross volume is 281 L and net volume is 193 L. The glass door and LED lighting allow contents to be viewed without opening the door. Select the storage setting for each product according to its manufacturer’s instructions.
TEMPERATURE+2…+10 °CAdjustable range
VOLUME281 / 193 LGross / net
DOORGlassLock and self-closing
ENERGY CONSUMPTION0.826 kWhPer 24 h, +5 °C setpoint²
EXTERNAL DIMENSIONS595 × 595 × 1560 mm¹Width × depth × height
INTERNAL DIMENSIONS500 × 415 × 1282 mmWidth × depth × height
Features for everyday use
- Danfoss controller — digital temperature display and Bluetooth.
- Visual alarms — temperature, open door and probe failure.
- Dual Air Stream — fan-assisted air circulation.
- Automatic defrost and energy-saving ECO mode.
- Four full shelves and one half shelf — flexible storage.
- Lock and self-closing door — controlled access to contents.
Technical specifications
Volume
| Gross volume | 281 L |
| Net volume | 193 L |
Dimensions and weight
| External dimensions (W × D × H)¹ | 595 × 595 × 1560 mm |
| Internal dimensions (W × D × H) | 500 × 415 × 1282 mm |
| Net weight | 70 kg |
| Gross weight | 72 kg |
Controls and electronics
| Controller | Danfoss |
| Temperature display | Three digits |
| High / low temperature alarm | Visual |
| Open door alarm | Visual |
| Probe failure alarm | Visual |
| USB connection | No |
| Built-in data logging | No |
| Temperature graph on display | No |
Additional control features
| Bluetooth connection | Yes |
| Controller battery backup | No |
| Safety thermostat | No |
| Dry contact | No |
| External probe porthole | Ø 12.7 mm |
| Reference bottle | No |
Temperature specifications
| Minimum operating temperature | +2 °C |
| Maximum operating temperature | +10 °C |
| Pull-down time to +6 °C² | 24 min |
| Hold-over time to +10 °C² | 78 min |
Cooling
| Air distribution | Dual Air Stream |
| Evaporator fan | Yes |
| Condenser fan | No |
| Number of compressors | 1 pcs |
| Variable-speed compressor | No |
| Number of probes | 2 pcs |
| Defrost | Automatic |
| Refrigerant | R600a |
| Refrigerant charge | 50 g |
Electrical and energy specifications
| Rated voltage | 230 V |
| Frequency | 50 Hz |
| Energy consumption per 24 hours² | 0.826 kWh |
| Annual energy consumption² | 302 kWh |
| Power during pull-down | 0.20 kW |
| Power in stable operation | 0.18 kW |
| Average heat rejection³ | 50 W |
| Noise level | 45 dB |
| Energy class | B |
Cabinet, door and supports
| Outer cabinet material | Painted steel |
| Inner cabinet material | White polystyrene (PS) |
| Insulation | Polyurethane with cyclopentane |
| Insulation thickness | 42 mm |
| Door type | Glass |
| Lock | Yes |
| Lighting | LED in door frame |
| Front feet | 2 pcs |
| Rear wheels | 2 pcs |
Door and operating conditions
| Self-closing door | Yes |
| Reversible door | Yes |
| Door hold-open at 90° | No |
| Maximum ambient temperature | +32 °C |
| Maximum relative humidity | 65 % |
Chamber equipment
| Full shelves | 4 pcs |
| Half shelf | 1 pcs |
| Full shelf load limit | 20 kg |
| Half shelf load limit | 11 kg |
| Shelf material per specification⁴ | Perforated stainless steel |
| Full / half shelf positions | 15 / 2 |
Packaging
| Packaging dimensions (W × D × H) | 636 × 671 × 1625 mm |
| Packaging weight | 2 kg |
¹ Dimensions follow the table on datasheet page 1. The drawing on page 3 gives a width of 600 mm; confirm the supplied version before installation. ² Manufacturer data at +20 °C ambient; energy consumption at a +5 °C setpoint. Hold-over time is not a guaranteed safe storage period for medicines. ³ Rounded up by the manufacturer to the nearest 50 W. ⁴ The table specifies perforated stainless steel, while the introduction mentions glass; confirm shelf configuration when ordering.
Application and configuration
For pharmacies and healthcare facilities. This is not a freezer. Built-in logging, USB, dry contact and controller battery backup are not provided. Independent temperature records require a separate monitoring solution; the probe port does not mean a logger is included. Bluetooth alone does not establish remote monitoring or cloud logging capability.