Quantity
|
Total
|
||
|
|
|||
|
|
|||
Vestfrost R-350 Essential is an upright pharmacy refrigerator with a glass door for storing vaccines and medicines in pharmacies and healthcare facilities. It has a gross volume of 350 L and a usable volume of 255 L. LED lighting lets staff check the shelves without opening the door.
Vaccine storage. The refrigerator operates from +2 to +10 °C. For vaccines labelled for storage at +2 to +8 °C, set the refrigerator accordingly and monitor the actual temperature inside the cabinet.
Key benefits
- Danfoss controller — digital temperature display and Bluetooth.
- Visual alarms — temperature, open door and probe failure.
- Dual Air Stream — fan-assisted air circulation.
- Automatic defrost and energy-saving ECO mode.
- Five full shelves and one half shelf — flexible storage.
- Lock and self-closing door — controlled access to contents.
Technical specifications
| Volume | |
|---|---|
| Gross volume | 350 L |
| Net volume | 255 L |
| Dimensions and weight | |
| External dimensions (W × D × H) | 595 × 595 × 1860 mm |
| Internal dimensions (W × D × H) | 500 × 415 × 1550 mm |
| Net weight | 79 kg |
| Gross weight | 81 kg |
| Controls and electronics | |
| Controller | Danfoss |
| Temperature display | Three digits |
| High / low temperature alarm | Visual |
| Open door alarm | Visual |
| Probe failure alarm | Visual |
| USB connection | No |
| Built-in data logging | No |
| Temperature graph on display | No |
| Additional control features | |
| Bluetooth connection | Yes |
| Controller battery backup | No |
| Safety thermostat | No |
| Dry contact | No |
| External probe porthole | Ø 12.7 mm |
| Reference bottle | No |
| Temperature specifications | |
| Minimum operating temperature | +2 °C |
| Maximum operating temperature | +10 °C |
| Pull-down time to +6 °C | 27 min |
| Hold-over time to +10 °C | 69 min |
| Cooling | |
| Air distribution | Dual Air Stream |
| Evaporator fan | Yes |
| Condenser fan | No |
| Number of compressors | 1 pcs |
| Variable-speed compressor | No |
| Number of probes | 2 pcs |
| Defrost | Automatic |
| Refrigerant | R600a |
| Refrigerant charge | 50 g |
| Electrical and energy specifications | |
| Rated voltage | 230 V |
| Frequency | 50 Hz |
| Energy consumption per 24 hours | 0.962 kWh |
| Annual energy consumption | 351 kWh |
| Power during pull-down | 0.18 kW |
| Power in stable operation | 0.16 kW |
| Average heat rejection | 50 W |
| Noise level | 45 dB |
| Energy class | B |
| Cabinet, door and supports | |
| Outer cabinet material | Painted steel |
| Inner cabinet material | White polystyrene (PS) |
| Insulation | Polyurethane with cyclopentane |
| Insulation thickness | 42 mm |
| Door type | Glass |
| Lock | Yes |
| Lighting | LED in door frame |
| Front feet | 2 pcs |
| Rear wheels | 2 pcs |
| Door and operating conditions | |
| Self-closing door | Yes |
| Reversible door | Yes |
| Door hold-open at 90° | No |
| Maximum ambient temperature | +32 °C |
| Maximum relative humidity | 65 % |
| Chamber equipment | |
| Full shelves | 5 pcs |
| Half shelf | 1 pcs |
| Full shelf load limit | 20 kg |
| Half shelf load limit | 11 kg |
| Shelf material per specification | Perforated stainless steel |
| Full / half shelf positions | 21 / 2 |
| Packaging | |
| Packaging dimensions (W × D × H) | 636 × 671 × 1925 mm |
| Packaging weight | 2 kg |
Applications and limitations
When vaccines require a continuous temperature record, use a separate data logger. The cabinet has a 12.7 mm port for an external probe. The controller has no built-in logging, USB, dry contact or battery backup.
This refrigerator is unsuitable for frozen storage. The controller supports Bluetooth. Remote monitoring or cloud logging requires a separate system.
Technical description Vestfrost R-350 Essential (PDF in Ukrainian)