Quantity
|
Total
|
||
|
|
|||
|
|
|||
Vestfrost Solutions R-138i — professional pharmaceutical / biomedical refrigerator for controlled storage in the specified temperature range. Select the operating setpoint for the requirements of the stored material.
Key features
- Controller: i-Care, 5-inch touchscreen
- Alarms: High/low temperature, door open, power failure, sensor fault
- Logging: Data, alarms and events; temperature graph
- Door type: Solid, lockable, self-closing, with hold-open above 90°
- Probe reference container: Yes
- External probe port: Ø 20 mm
Technical specifications
| Model | R-138i |
|---|---|
| Equipment type | Professional pharmaceutical / biomedical refrigerator |
| Door type | Solid, lockable, self-closing, with hold-open above 90° |
| Gross / net capacity, L | 138 / 117 |
| Temperature range | +2…+20 °C |
| Temperature uniformity | ±0.4 °C under manufacturer test conditions |
| Number of sensors | 4 |
| Air distribution | Dynamic |
| Defrost | Automatic |
| Controller | i-Care, 5-inch touchscreen |
| Logging | Data, alarms and events; temperature graph |
| Interfaces | USB, MODBUS, dry contact |
| Alarms | High/low temperature, door open, power failure, sensor fault |
| Backup battery | For the controller, up to 24 hours; does not power the compressor |
| External probe port | Ø 20 mm |
| Probe reference container | Yes |
| Safety thermostat | Yes |
| Lock | Yes |
| Interior lighting | LED |
| Shelves | 2 full-size + 1 half-size, perforated aluminium |
| Cabinet / chamber material | Painted steel / ABS |
| Insulation | Polyurethane with cyclopentane, 50 mm |
| External dimensions (H × W × D), mm | 825 × 595 × 642 |
| Internal dimensions (H × W × D), mm | 676 × 475 × 425 |
| Gross / net weight, kg | 56 / 45 |
| Maximum ambient temperature | +35 °C |
| Maximum relative humidity | 75% |
| Noise level | 44 dB |
| Energy consumption | 0.334 kWh/24 h; 121.9 kWh/year |
| Refrigerant | R600a, 47 g |
| Compressor | 1, variable capacity |
| Power supply | 230 V / 50–60 Hz |
| Mobility | Adjustable feet; castors optional |
Application and configuration
Use only for materials whose storage requirements fall within the stated temperature range. Confirm the required usable capacity, container layout, ambient conditions and installation clearances before ordering. Energy consumption, uniformity and holdover figures apply to the stated test conditions. A controller backup battery supports monitoring and alarms; it does not power the compressor.
Compare specifications: Pharmaceutical Refrigerator R-90i (+2…+20 °C, 90 L)