Vestfrost R-90i. For pharmacies, laboratories and healthcare facilities. The solid door shields stored items from light, and the interior LED helps staff locate medicines.
Vaccine storage. For vaccines labelled for storage at +2 to +8 °C, set the refrigerator accordingly and monitor the actual temperature. The cabinet operates from +2 to +20 °C.
Key benefits
- i-Care touchscreen controller, temperature and alarm logs, USB
- High and low temperature, door open and probe failure alarms
- Forced air circulation and automatic defrost
- Lock and reversible self-closing door
- One full shelf and one half shelf in perforated stainless steel
- Dry contact and external probe port
Technical specifications
| Volume | |
|---|---|
| Gross volume | 90 L |
| Usable volume | 76 L |
| Dimensions and weight | |
| External dimensions (W × D × H) | 595 × 642 × 672 mm |
| Internal dimensions (W × D × H) | 475 × 495 × 481 mm |
| Net weight | 38 kg |
| Gross weight | 48 kg |
| Controls and alarms | |
| High and low temperature alarm | Yes |
| Door open alarm | Yes |
| Probe failure alarm | Yes |
| USB connection | Yes |
| Data logging | Yes |
| Dry contact | Yes |
| External probe port | Ø 20 mm |
| Interior lighting | LED |
| Temperature performance | |
| Minimum temperature | +2 °C |
| Maximum temperature | +20 °C |
| Mean cabinet temperature during test | 4.6 °C |
| Temperature uniformity under test conditions | ±0.6 °C |
| Average temperature stability | 0.3 °C |
| Recovery to a mean of +6 °C after the door was open for 1 min | <1 min |
| Pull-down to a mean of +6 °C | 28 min |
| Warm-up from +5 to +10 °C | 61 min |
| Cooling | |
| Air distribution | Forced air |
| Defrost | Automatic |
| Refrigerant | R600a, 39 g |
| Power and energy | |
| Supply voltage | 230 V |
| Mains frequency | 50–60 Hz |
| Energy use per 24 h at the +5 °C set point | 0.290 kWh |
| Noise level | 46 dB |
| Cabinet and door | |
| Exterior material | Painted steel |
| Cabinet lining | ABS |
| Insulation thickness | 50 mm |
| Insulation material | Polyurethane with cyclopentane |
| Standard door | Solid |
| Self-closing door | Yes |
| Hold-open above 90° | Yes |
| Reversible door | Yes |
| Lock | Yes |
| Standard feet | Adjustable feet |
| Shelves | |
| Full-size shelf | 1 |
| Half shelves supplied | 1 |
| Shelf material | Perforated stainless steel |
| Equipment and options | |
| Castors | Optional |
| Safety thermostat | Yes |
| Power failure alarm | Yes |
| Controller battery backup | 24 h |
| Test conditions | |
| Measurement points | 15 pcs |
| Cabinet condition during test | Empty |
| Ambient test temperature | +20 °C |
| Relative humidity during test | 60 % |
| Test set point | +5 °C |
| On time per cycle | 5.5 min |
| Off time per cycle | 10.2 min |
| Duty cycle | 34.7 % |
Applications and limitations
The safety thermostat, power failure alarm and 24-hour controller battery are standard. Cooling during a power outage requires an external power source. Castors are optional.
Vestfrost R-90i manufacturer datasheet (PDF, English)
Compare with another model: Vestfrost AKS 337.