Quantity
|
Total
|
||
|
|
|||
|
|
|||
This 65 L benchtop PharmaSafe refrigerator fits a pharmacy, treatment room or laboratory. The glass door lets staff see the contents at a glance. Temperature records can be downloaded via USB.
Gallery images 2 and 3 visualize placement options. Image 4 is a visualization of the open chamber.
Image captions
- Product image · Front view with glass door
- Interior visualization · On a pharmacy worktop
- Interior visualization · Position in a treatment room
- Chamber visualization · Open chamber with adjustable and bottom shelves
- Product detail · Control panel, door lock and USB port
Key features
- Forced-air cooling and automatic defrost.
- TC-100 controller and a digital display with 0.1 °C resolution.
- USB data storage and a remote alarm contact; cloud monitoring is optional.
- Door lock, internal LED lighting and a test access port.
Before ordering
The table describes the current PharmaSafe revision. Dimensions, weight, power and equipment differ from the previously listed Classic revision. The agreed specification and the individual unit data sheet determine the supplied configuration.
Technical specifications
| Model | MPR-68 |
|---|---|
| Capacity, L | 65 |
| Temperature, °C | +2…+8 |
| Internal dimensions (W×D×H), mm | 410 × 391 × 420 |
| External dimensions (W×D×H), mm | 510 × 590 × 660 |
| Net / gross weight, kg | 34 / 42 |
| Rated power by electrical version, W | 118 / 118 / 100 |
| Adjustable shelves + bottom shelf | 1 + 1 |
| Rated current by electrical version, A | 1.0 / 1.0 / 1.2 |
| Electrical versions | 220 V / 50 Hz; 220 V / 60 Hz; 120 V / 60 Hz |
| Refrigerant | R600a |
| Controller | TC-100 |
| Display resolution, °C | 0.1 |
| Test access port | Φ19 mm × 1 |
| USB / remote alarm contact | Included / included |
| Cloud monitoring | Optional |
| Standard door | One double-glazed door |
| Alarm indication | Audible and visual |
Frequently asked questions
How should storage capacity be selected?
Consider container dimensions, quantity, rack layout and space needed for air circulation or sample retrieval. Nominal chamber volume is not the same as usable loaded volume.
Does a 0.1 °C display imply 0.1 °C temperature uniformity?
No. Display resolution, stability over time and spatial temperature uniformity describe different properties. Validate the usable storage area through temperature mapping under the agreed protocol.
What should be confirmed before delivery?
Confirm the exact model revision, electrical supply, door arrangement, access route, ventilation clearance, shelves or racks, monitoring and backup provision. List optional accessories separately in the order specification.
Does the alarm battery run the cooling system?
An alarm backup battery in a stationary freezer does not power its compressors. Continued cooling requires suitable backup power or a compatible backup cooling system. Portable freezer run time depends on the actual battery and operating conditions.
Useful links
Compare models and select equipment: Vaccine refrigerators +2…+8 °C.