AAS-2610 atomic absorption spectrometer

Out of stock
SKU: AAS-2610
Description

AAS-2610 is a flame atomic absorption spectrometer with a two-position lamp turret for sequential metal analysis in prepared solutions. Lamps, calibration standards and sample preparation are selected for the target elements and sample matrices.

WAVELENGTH RANGE190–900 nmAtomic absorption analysis
LAMP TURRET2Positions; lamps supplied separately
BURNER100 mmTitanium, air–acetylene

Key advantages

  • Flame atomisation supports routine elemental analysis of prepared liquid samples.
  • A two-position turret accommodates lamps for selected elements.
  • Four bandwidth settings adapt the optics to the analytical line.
  • A titanium burner and glass nebuliser are combined with a corrosion-resistant spray chamber.
  • Software supports calibration curves, standard additions and replicate statistics.
  • An optional hydride generator extends suitable element-specific methods.

Technical specifications

AtomisationAir–acetylene flame
Wavelength range190–900 nm
Lamp turret2 positions; lamps not included
Spectral bandwidth0.2 / 0.4 / 1.0 / 2.0 nm
Wavelength accuracy / repeatability±0.10 / 0.05 nm
Monochromator / detectorC-T / photomultiplier
Published Cu detection limit0.003 µg/mL under specified test conditions
Published precisionRSD ≤0.5% under specified test conditions
BurnerTitanium, 100 mm
Power supply220 V, 50 Hz; 150 VA
Dimensions / weight1000 × 350 × 390 mm; 70 kg
Operating environment10–35 °C; relative humidity ≤80%

Application and configuration

Analysis of water, raw materials, food and other samples requires suitable preparation and a validated method. The listed base package comprises the instrument, oil-free compressor, software, accessories and transport packaging. Hollow-cathode lamps, PC and printer are excluded. Hydride generation and oxygen enrichment are optional; a graphite furnace is not specified. Suitable gas supplies and extraction are required. The catalogue lists Windows 98/2000/XP software, so the current software version, computer and operating-system compatibility must be specified. The Cu detection limit is not a universal limit for all elements or matrices.

Atomic absorption spectrometers

Compare with: AAS-2630 — flame and graphite furnace.

AAS-2610 / AAS-2630 technical catalogue