Antech CryoMatrix 19K — An automated cryogenic storage system with liquid-nitrogen autofill and temperature and LN₂ level monitoring. The sample inventory system is selected for vials, straws or bags and the laboratory workflow.
Key advantages
- Automatic filling operates from a compatible external LN₂ supply.
- The touchscreen displays temperature, nitrogen level and alarms.
- Data logging and USB support storage and export of events.
- The defog function helps with sample access.
- The warm-gas bypass reduces warm gas entry during filling.
- Racks and cassettes are selected for sample dimensions and the required storage phase.
Technical specifications
| Model | Antech CryoMatrix 19K |
|---|---|
| 1.2/2 mL capacity, current table | 21000 |
| Total LN₂ capacity | 460 L |
| Large / small racks | 12 / 8 |
| 2-inch boxes per rack | 15 |
| Neck opening | 320 mm |
| Outer diameter | 820 mm |
| Overall height | 1600 mm |
| Empty weight | 264 kg |
| Controller | Touchscreen |
| Automatic filling | Standard |
| Data storage and USB | Standard |
| Defog | Standard |
| Wi-Fi / cloud connection | Optional |
| Racks and vacuum-jacketed hose | Options as specified |
Application and configuration
For CryoMatrix 19K, the current manufacturer table specifies 21000 1.2/2 mL vials, while this listing title retains the previous 19400 figure. The table here follows the current catalogue; confirm the product revision, racks and actual capacity before ordering.
CryoMatrix is specified for −190 °C vapour-phase storage. The 48-hour open-lid statement refers to a factory test remaining below −150 °C, not a guarantee of maintaining −190 °C with the lid open.
Before installation, check the delivery path, floor loading, room ventilation and LN₂ connection. Agree supply pressure, fittings, hose, alarms and the power-failure procedure.
Specify backup power, Wi-Fi, cloud access, racks, boxes and a vacuum-jacketed hose in the supply configuration. The CryoMatrix page contains differing battery statements; confirm inclusion for the specific package.
The photo illustrates the series using Antech CryoMatrix 15K; it is not an exact image of this model. Dimensions and configuration are defined by the agreed specification.
Is an electrical connection sufficient?
No. Cooling and autofill require liquid nitrogen and a compatible LN₂ supply.
Is capacity the same for all sample formats?
No. Capacity depends on the vials, boxes, bags, cassettes and rack system.